In-service inspection & testing
Piping, tanks and pressure vessels.
API 570 piping, API 653 and API 620 tank, and API 510 and AS/NZS 3788 pressure vessel inspections by certified inspectors, backed by our own NDT crew. Reports give you remaining life and the next inspection date.
- API 570
- API 653
- API 620
- API 510
- AS/NZS 3788
- AS 1940
- AS 1692
- AICIP
Do you need it?
How long has it got left? The inspection tells you.
An in-service inspection checks your piping, storage tanks and pressure vessels against their inspection code while they're in use. It tells you what needs fixing, what can wait, how much life is left and when to look again.
Our API 570, API 653, API 510 and AICIP inspectors run the inspection, and our own technicians do the NDT. Thickness readings, scans and findings go into one report, with minimum thickness, corrosion rates and remaining life worked out for you.
- 01
Certified inspectors
API 570, API 653, API 510 and AICIP.
- 02
Our own NDT
Floor scanning, B-scan, PAUT, UT, MT, eddy current and vacuum box, done in-house.
- 03
Remaining life
Corrosion rates, remaining life and the next inspection date in the report.
- 04
Testing too
NATA accredited relief valve and hydrostatic testing, up to 100,000 kPa.
Storage tanks · API 653, API 620, AS 1940 & AS 1692
Floor to roof, one inspection.
Our API 653 inspectors work through the tank from the foundation to the roof, with the NDT done by our own technicians. Atmospheric API 650 tanks are inspected to API 653, and low-pressure API 620 tanks to the same principles against their design code. Findings are tied back to the code and to AS 1940 and AS 1692.
01
Floor plates
Every plate scanned with our encoded MFL floor scanner, and indications proved up with UT.
02
Critical zone & annular
UT and PAUT where the floor meets the shell, scanned separately from the rest of the floor.
03
Shell courses
B-scan buggy and UT on every course, with tmin worked out course by course.
04
Nozzles & manways
Necks to API 653 4.3.9, and manway covers checked against API 650.
05
Roof
UT and visual, with IRATA rope access where there's no safe walkway.
06
Welds, foundation & coatings
MT, eddy current and vacuum box on welds. Foundation and chime checked, and coatings by AMPP (NACE) inspectors.
The kit
Scan the floor. Profile the shell.
Floors
MFE Mark IV floor scanner
Encoded MFL scanning of every floor plate picks up metal loss on the product side and the soil side, so underside corrosion isn't missed. Indications are proved up with UT, and every plate is mapped and numbered.
Shells
Magnetic B-scan buggy
Magnetic wheels hold the buggy to the shell while it records an encoded B-scan: a continuous thickness profile up the wall instead of a handful of spot readings. Every reading exports to CSV.
Where it's thin, we map it. HydroFORM 2 and RollerFORM C-scans on shell courses, the critical zone and nozzles, including under scale that can't be cleaned, feed straight into the tmin and remaining-life numbers. See PAUT corrosion mapping.
The report
Remaining life, worked out for you.
Each tank gets its own API 653 report. Minimum thickness is calculated for every shell course, corrosion rates and remaining life are plotted for the shell and the floor, and every finding is rated and photographed.
Minimum thickness
Shell tmin to API 653 4.3.3.1, the greater of the product and hydrotest cases. Floor minimum to API 653 Table 4.4.
Rate and remaining life
Plotted for the shell and the floor, with the next inspection date.
Findings rated
Negligible, low, medium, high or extreme, each with a photo.
Piping & pressure vessels
Piping and vessels, inspected to the code.
Piping · API 570 · AS/NZS 3788
Piping
- Thickness monitoring at CMLs, with a corrosion rate and remaining life for every circuit
- Corrosion under insulation: profile radiography through the lagging
- Elbows and bends mapped with FlexoFORM PAUT
- Dead legs, injection points and small-bore lines
Vessels · API 510 · AS/NZS 3788
Pressure vessels
- Internal and external inspections by API 510 and AICIP certified inspectors
- Shells, heads and nozzles thickness-checked, with PAUT mapping where it's thin
- Remaining life and the next inspection date for every vessel
- Repairs, re-rating advice and the pressure test, in one place
- Leeb and Brinell hardness on welds, HAZ and parent metal


Testing
Relief valves, pressure tests and vacuum box.
NATA accredited
Pressure relief valves
Inspection, overhaul and certification on our test bench. Set pressure and seat leakage tested by air or water to AS 1271 and API 527, NATA accredited up to 100,000 kPa. PRV testing
NATA accredited
Hydrostatic testing
When a repair or alteration calls for a pressure test, we do that too. Piping and vessels tested to AS 1210, AS/NZS 3788, AS 4041, ASME VIII and B31.3, NATA accredited up to 100,000 kPa. Hydrostatic testing
Tank floors
Vacuum box testing
Floor lap welds leak tested with flat vacuum boxes, and the shell-to-floor corner weld with right-angle boxes. To API 650, API 653 and ASME V Article 10.
Made to suit
Custom sump boxes
Sumps and other awkward shapes don't suit a standard box, so we make custom vacuum boxes to fit, each with its own calibrated gauge.
Our inspectors
Certified to the code they inspect to.
- NATA 12303
- ISO 9001
- API
- AICIP
- AINDT
- IRATA
Brochure
Piping, tanks and pressure vessels
API 510, 570 and 653 inspections, remaining life, floor scanning and vacuum box.
4 pages · PDF 0.8 MB
Get in touch
How long have your assets got left?
Swift reporting, round the clock.