DITS technicians mapping hull plate with a phased array scanner and an OmniScan X4

Phased array corrosion mapping

See the whole plate, not just the point.

Encoded phased array corrosion mapping for ship hulls, storage tanks, pipelines and pressure vessels. Every scan is recorded reading by reading and handed back as colour maps and data you can use.

  • Ship hulls
  • Storage tanks
  • Pipelines & piping
  • Pressure vessels
  • Elbows & bends
  • Repeat surveys
  • CSV export

Do you need it?

A spot reading checks a point. A corrosion map checks the plate.

Thickness gauging takes one reading at a time on a grid, and corrosion doesn't follow the grid. Pitting, grooving and patches of wall loss sit between the points and never get measured.

Encoded phased array scans the whole area in one pass and records a reading every millimetre, so the thinnest spot is found, measured and located instead of missed. If you're deciding on steel renewal, a repair or the remaining life of an asset, that's the reading you need.

Spot UT on a 60 mm grid 20 readings

Lowest of the 20 grid readings: –. On paper, the plate looks fine.

PAUT C-scan, same plate 60,000 readings

Lowest reading on the map: –. The pitting sits between the grid points.

Example data Same 300 × 200 mm plate in both panels, 10 mm nominal. ThinNominal
  1. 01

    Full coverage

    100% of the scan area, not a sample of it.

  2. 02

    Encoded & repeatable

    Every reading tied to a position. Re-scan the same area next time and compare.

  3. 03

    Finds mid-wall damage

    Laminations and inclusions told apart from true wall loss.

  4. 04

    Stays in service

    Scanned from the outside while the asset keeps running.

Marine

Ship hull scanning

Hull plate loses steel where it's hardest to see: along the waterline, around the bilge and behind ballast tank coatings. We map whole plates on the hardstand, in dry dock or from inside the tanks, so steel renewal is decided on measured wall, not a guess between readings.

  • Side shell and boot-top, where wet and dry cycling thins plate fastest
  • Bottom and bilge plating, mapped plate by plate in dock
  • Ballast, fuel and void tank boundaries, scanned from inside
  • Decks, hatch coamings and bulkheads

RollerFORM covers large plates fast; HydroFORM 2 gives high-resolution detail. Results are laid out by strake and frame, ready for your surveyor and the repair yard.

Tanks, pipelines & vessels

The same map, across the rest of your plant.

We scan from the outside with the asset in service, and each map feeds straight into our API 653 and API 510 assessments for minimum thickness and remaining life.

Storage tanks

Shell courses, nozzles and roof plate, from inside or out. Maps feed straight into API 653 minimum-thickness and remaining-life calculations.

HydroFORM 2 · RollerFORM

Pipelines & piping

Straight runs mapped along and around the pipe. Elbows and bends, where erosion and flow-accelerated corrosion bite hardest, mapped with the FlexoFORM wrap-around array.

HydroFORM 2 · FlexoFORM

Pressure vessels

Shells, heads and nozzles mapped for wall loss, plus the mid-wall laminations and inclusions a spot gauge can mistake for corrosion. Supports our API 510 in-service inspections.

HydroFORM 2 · OmniScan X4

DITS technician mapping a pipe with a phased array scanner, OmniScan X4 on the pipe
Piping mapped in service.
Exposed pipeline in an excavation with wall loss marked on the steel
Buried pipelines, at the dig: we map the exposed pipe and mark the wall loss on the steel.

Repeat surveys

Scan it again. Measure the rate.

Every reading is encoded to a datum, so the next survey covers exactly the same steel. Subtract one map from the other and you get a measured corrosion rate at every point, not an estimate from two spot readings.

Same steel, every time

Scan start points and directions are recorded against the datum, so each survey repeats the last.

A rate at every point

The worst spot sets the life, and the map shows exactly where it is.

Into the assessment

Rates and minimums go straight into our API 653 and API 510 remaining-life calculations.

Your data

Every reading, in a spreadsheet.

Any C-scan can be exported as a CSV file holding every thickness reading at its scan and index position, colour-coded to the same scale as the map. Open it in Excel, sort for the minimums, run your own remaining-life numbers or load it into your asset management system. Your data stays yours.

C-scan maps
Minimum and average wall for each zone
CSV export
Every reading, positioned and colour-coded
Scan images
A, B and C-scan views of anything flagged
Raw data
Scan files kept for re-scans and trending

The kit

Evident (Olympus) phased array, run in-house.

Instrument

OmniScan X4

Phased array instrument. Every scan encoded, recorded and kept.

Corrosion

HydroFORM 2

Water-wedge mapping scanner. High-resolution maps on plate and pipe, even on rough surfaces.

Elbows

FlexoFORM

Flexible array that wraps around elbows and bends, the areas spot UT finds hardest.

Large areas

RollerFORM

Wheel probe that rolls across hull plate and tank shells at speed.

Scanning welds rather than wall? See PAUT and ToFD weld inspection.

  • NATA 12303
  • ISO 9001
  • DNV
  • API
  • AINDT
  • PCN
  • IRATA
Cover of the DITS PAUT corrosion mapping brochure

Brochure

PAUT corrosion mapping

In-service hulls, tanks, pipelines and vessels. See the whole picture, not just spots.

4 pages · PDF 1.6 MB

View Download PDF

Get in touch

Need to know how much steel you have left?

Swift reporting, round the clock.