
Phased array & time-of-flight diffraction
See inside the weld. No radiation.
Phased array (PAUT) and ToFD weld inspection for plate, pipe, tank and rail welds. Every weld is scanned from both sides, encoded along its length and kept as a digital record. No exclusion zone, so other crews keep working.
- Plate & pipe welds
- Tank welds
- Rail welds
- ToFD height sizing
- ASME V
- API 650 Annex U
- Level 3 scan plans
Do you need it?
Inside the weld, without clearing the site.
PAUT and ToFD are ultrasonic weld tests. They find flaws inside a weld and measure how deep and how tall they are, using sound instead of radiation. If you need welds volumetrically tested and can't stop work or barricade an area for radiography, this is the method.
Radiography needs an exclusion zone, often out of hours, to keep people clear of the beam. With PAUT and ToFD we scan while everyone else keeps working, and each flaw is sized through the wall, not just seen from above.
- 01
Both sides
Every weld scanned from both sides, aimed at the fusion faces.
- 02
One pass
PAUT and ToFD encoded together along the weld.
- 03
Flaw height measured
Through-wall height from the ToFD tip signals.
- 04
No radiation
No barricades and no clearing the area.
PAUT or radiography?
We do both, and we'll tell you which suits the job.
Radiography
A flat picture of the weld
- Exclusion zone and barricades; nearby work stops while shots are taken
- Flaw height isn't measured
- Lack of fusion and cracks can be missed if they don't line up with the beam
- Source on one side, film or plate on the other
- Record is a film or a CR image
PAUT + ToFD
The weld in cross-section
- No radiation; crews keep working around us
- Through-wall height measured from the ToFD tip signals
- Angled beams from both sides aimed at the fusion faces
- Access from one surface only
- Encoded data file of the whole weld, re-analysed any time
Radiography still suits thin welds, small bore and some joint types. See radiography.
How it works
Sectorial scans from both sides, encoded along the weld.
A phased array probe sweeps the beam through a range of angles, so the X4 shows the weld in cross-section at true depth. Scanning from both sides of the weld and recording position along its length gives full volumetric coverage in one pass, and a permanent digital record of every weld.
Each indication is located along the weld and sized for length, depth and height.
Time-of-flight diffraction · ToFD
ToFD measures the height of the flaw.
A transmitter and a receiver straddle the weld. Sound diffracts off the top and bottom tips of a flaw, and the time between those two signals gives its through-wall height, not how loud the echo is. We run ToFD with PAUT in the same encoded pass on the X4.
ToFD can't see just under the scan surface or right at the backwall. The PAUT sectorial scans cover both.
What we scan
Plate, pipe, tank and rail welds.
Plate & pipe welds
New build, repairs and in-service welds, with indications sized for length, height and depth.
Tank welds
Shell welds on new tanks, where API 650 Annex U allows ultrasonic examination in place of radiography.
Rail welds
Low-frequency 2.25 MHz arrays get through the coarse grain of rail welds. Every weld recorded.
NATA accredited (No. 12303) for PAUT weld inspection: steel, stainless and aluminium. Scan plans are reviewed by a Level 3, to ASME V, API 650 Annex U or your ITP, and welds are accepted against the construction code you nominate.
How a weld job runs
Planned, scanned, sized and called.
- 01
Scan plan
Probes, wedges, angles and positions set for the joint, and reviewed by a Level 3.
- 02
Set-up
Sensitivity and depth set on a reference block before scanning, and checked again after.
- 03
Scan
Encoded scans from both sides of the weld, PAUT and ToFD in the same pass.
- 04
Analyse
Every indication located along the weld and sized for length, depth and height.
- 05
Report
Accept or reject against the code you nominate, with the images and data behind each call.
What you get
Every indication, located and sized.
Each weld comes back with an indication table, the S-scan and ToFD images behind every call, and the encoded data file. Re-open the data any time to check a call, or compare at the next inspection.
- Indication table
- Position from datum, length, depth, height, type and result
- Scan images
- S-scan and ToFD views behind every call
- Data file
- The encoded scan of the whole weld
- A clear call
- Accept or reject against the nominated code
What we need from you
Four things.
- Joint details from the WPS: thickness, bevel and weld process
- The code and acceptance criteria that apply
- A weld map or drawing with weld numbers
- Access along both sides of the weld, with spatter and loose scale removed
The kit
Evident (Olympus) phased array, run in-house.
Instrument
OmniScan X4
Phased array flaw detector. PA, UT and ToFD, with every scan encoded and recorded.
Probes
Weld and ToFD probes
Linear arrays and wedges from 2.25 MHz for rail welds up to 7.5 MHz, plus our own ToFD probes. Anything special for a job, we order in.
Set-up check
Reference blocks
Sensitivity and depth set on a reference block before any weld is scanned, and checked again after.
Planning
Level 3 scan plans
Every scan plan reviewed by a Level 3 before the job starts.
Measuring wall loss rather than weld flaws? See PAUT corrosion mapping.
- NATA 12303
- ISO 9001
- AINDT
- PCN
Brochure
PAUT and ToFD weld inspection
Full weld coverage in one encoded pass, with ToFD for through-wall height.
4 pages · PDF 0.8 MB
Get in touch
Welds to inspect? Keep the site running.
Swift reporting, round the clock.
