HAND-X wireless remote held up in front of the Balteau CERAM 235 X-ray tube in the DITS radiation bay

Gamma, X-ray & computed radiography

See inside the weld, in the bay or on site.

Weld and pipe radiography from Darwin: licensed two-person crews, a shielded radiation bay at our premises, and transportable darkrooms for film on remote sites. Read by AINDT Level 2 technicians and assessed to your code.

  • Gamma
  • X-ray
  • Computed radiography
  • Pressure equipment
  • Welder quals
  • Wall thickness
  • NATA film RT

Do you need it?

A permanent picture of every weld.

Radiography records the full volume of a weld on film or a digital plate. Porosity, slag, lack of fusion and cracks show up as an image you can hold, review and keep. If your code, client or ITP calls for radiographed welds, or you need a record that stays with each weld, this is the method.

Every exposure carries an image quality indicator (IQI) and lead identification, so each result traces back to the weld it came from. Our procedure calls for a film density of 2.0 to 4.0 across the area of interest.

  1. 01

    Traceable

    An IQI, lead ID and location markers on every film.

  2. 02

    To the code

    AS 2177, ASTM E94 and ASME V Article 2, assessed to your specification.

  3. 03

    Qualified

    Licensed two-person crews. Films read by AINDT Level 2, borderline calls to our Level 3.

  4. 04

    NATA accredited

    Film radiography of welds, NATA No. 12303.

Techniques

The right shot for the joint.

Single wall

Plate, vessels and large-bore pipe, shot through one wall from either side.

Panoramic

Gamma source centred in the pipe: the whole circumference in one exposure, with three IQIs at 120°.

Double wall, single image

Pipe with no inside access. The source sits outside, and the far wall is imaged.

Double wall, double image

Small-bore pipe: both walls in one elliptical image on the film.

Welder qualifications

Test coupons radiographed in our own bay, so welders aren't left waiting on results.

Repairs tracked

Repairs are marked R1, R2 and re-welds N1, N2 on the film, so each weld's history stays with it.

Bay and field radiography

In our bay or on your site.

Radiation bay

A shielded bay at our Darwin premises for spools, coupons and fabricated parts, with our darkroom, densitometers and film viewers. No exclusion zone on your site.

On site

Gamma and X-ray crews for plants, pipelines and remote sites, with the controlled area set up and monitored on calibrated survey meters.

Film processing

Automatic on our GE Structurix M ECO, or manual development with a separate film dryer. Transportable site-office darkrooms process film on remote jobs.

Sources

Gamma, X-ray or digital.

880 Delta × 2 · 880 Elite

Gamma

No power and no cooling, in a compact projector. The source goes where a tube can't: inside pipe for panoramic shots, tight access and remote sites.

CERAM 235 · Rigaku 200 kV · Rigaku 300 kV

X-ray

Sharper, higher-contrast images on thinner sections. Nothing to secure once the set is switched off, in the bay or on site.

DÜRR NDT HD-CR 35

Computed radiography

Reusable imaging plates in place of film, read to digital images you can zoom, measure, archive and email. No darkroom chemicals. CR is outside our NATA scope.

Pipe wall thickness

Profile radiography. Measure the wall, leave the lagging on.

Shot tangentially across the pipe, the wall shows in profile on the film. Wall loss, pitting and corrosion under insulation can be measured without stripping the lagging. Done to our procedure TESP-438.

  • Screens insulated lines for corrosion under insulation
  • Small-bore and hard-to-reach pipe
  • Wall measured off the film or the digital image

NATA accredited (No. 12303) for wall thickness by film radiography.

The kit

Gamma, X-ray, CR and film processing, in-house.

Gamma × 2

880 Delta

Gamma projectors. No power needed, for site, panoramic and remote work.

Gamma

880 Elite

Gamma projector, cranked out from a safe distance.

X-ray · 235 kV

Balteau CERAM 235

Fired from the HAND-X wireless remote, up to 100 m away.

X-ray · 200 kV

Rigaku 200 kV

X-ray set for thinner sections, in the bay or on site.

X-ray · 300 kV

Rigaku 300 kV

Higher-energy X-ray for thicker steel.

Digital

DÜRR NDT HD-CR 35

CR scanner: reusable plates read to digital images.

Auto processor

Structurix M ECO

GE automatic processor with cascade fixing and infrared drying.

On site

Site darkrooms

Transportable site offices fitted out to process film on remote jobs.

What you get

Films, a report and a clear call on every weld.

Films are assessed to the code or specification you nominate. Borderline indications go to our Level 3 before the call is made.

Need volumetric testing without an exclusion zone? See PAUT and ToFD weld inspection.

Films or images
Handed over for your records
Weld-by-weld report
Density, sensitivity and interpretation for each weld
Repair tracking
Repairs and re-welds marked and re-shot
Level 3 review
Borderline indications referred to our Level 3
  • NATA 12303
  • ISO 9001
  • AINDT
  • PCN
Cover of the DITS Radiography brochure

Brochure

Radiography

Gamma, X-ray and CR, in our radiation bay or on site.

4 pages · PDF 1.5 MB

View Download PDF

Get in touch

Need to see inside a weld?

Swift reporting, round the clock.