Gamma, X-ray & computed radiography
See inside the weld, in the bay or on site.
Weld and pipe radiography from Darwin: licensed two-person crews, a shielded radiation bay at our premises, and transportable darkrooms for film on remote sites. Read by AINDT Level 2 technicians and assessed to your code.
- Gamma
- X-ray
- Computed radiography
- Pressure equipment
- Welder quals
- Wall thickness
- NATA film RT
Do you need it?
A permanent picture of every weld.
Radiography records the full volume of a weld on film or a digital plate. Porosity, slag, lack of fusion and cracks show up as an image you can hold, review and keep. If your code, client or ITP calls for radiographed welds, or you need a record that stays with each weld, this is the method.
Every exposure carries an image quality indicator (IQI) and lead identification, so each result traces back to the weld it came from. Our procedure calls for a film density of 2.0 to 4.0 across the area of interest.
- 01
Traceable
An IQI, lead ID and location markers on every film.
- 02
To the code
AS 2177, ASTM E94 and ASME V Article 2, assessed to your specification.
- 03
Qualified
Licensed two-person crews. Films read by AINDT Level 2, borderline calls to our Level 3.
- 04
NATA accredited
Film radiography of welds, NATA No. 12303.
Techniques
The right shot for the joint.
Single wall
Plate, vessels and large-bore pipe, shot through one wall from either side.
Panoramic
Gamma source centred in the pipe: the whole circumference in one exposure, with three IQIs at 120°.
Double wall, single image
Pipe with no inside access. The source sits outside, and the far wall is imaged.
Double wall, double image
Small-bore pipe: both walls in one elliptical image on the film.
Welder qualifications
Test coupons radiographed in our own bay, so welders aren't left waiting on results.
Repairs tracked
Repairs are marked R1, R2 and re-welds N1, N2 on the film, so each weld's history stays with it.
Bay and field radiography
In our bay or on your site.
Radiation bay
A shielded bay at our Darwin premises for spools, coupons and fabricated parts, with our darkroom, densitometers and film viewers. No exclusion zone on your site.
On site
Gamma and X-ray crews for plants, pipelines and remote sites, with the controlled area set up and monitored on calibrated survey meters.
Film processing
Automatic on our GE Structurix M ECO, or manual development with a separate film dryer. Transportable site-office darkrooms process film on remote jobs.
Sources
Gamma, X-ray or digital.
880 Delta × 2 · 880 Elite
Gamma
No power and no cooling, in a compact projector. The source goes where a tube can't: inside pipe for panoramic shots, tight access and remote sites.
CERAM 235 · Rigaku 200 kV · Rigaku 300 kV
X-ray
Sharper, higher-contrast images on thinner sections. Nothing to secure once the set is switched off, in the bay or on site.
DÜRR NDT HD-CR 35
Computed radiography
Reusable imaging plates in place of film, read to digital images you can zoom, measure, archive and email. No darkroom chemicals. CR is outside our NATA scope.
Pipe wall thickness
Profile radiography. Measure the wall, leave the lagging on.
Shot tangentially across the pipe, the wall shows in profile on the film. Wall loss, pitting and corrosion under insulation can be measured without stripping the lagging. Done to our procedure TESP-438.
- Screens insulated lines for corrosion under insulation
- Small-bore and hard-to-reach pipe
- Wall measured off the film or the digital image
NATA accredited (No. 12303) for wall thickness by film radiography.
The kit
Gamma, X-ray, CR and film processing, in-house.
Gamma × 2
880 Delta
Gamma projectors. No power needed, for site, panoramic and remote work.
Gamma
880 Elite
Gamma projector, cranked out from a safe distance.
X-ray · 235 kV
Balteau CERAM 235
Fired from the HAND-X wireless remote, up to 100 m away.
X-ray · 200 kV
Rigaku 200 kV
X-ray set for thinner sections, in the bay or on site.
X-ray · 300 kV
Rigaku 300 kV
Higher-energy X-ray for thicker steel.
Digital
DÜRR NDT HD-CR 35
CR scanner: reusable plates read to digital images.
Auto processor
Structurix M ECO
GE automatic processor with cascade fixing and infrared drying.
On site
Site darkrooms
Transportable site offices fitted out to process film on remote jobs.
What you get
Films, a report and a clear call on every weld.
Films are assessed to the code or specification you nominate. Borderline indications go to our Level 3 before the call is made.
Need volumetric testing without an exclusion zone? See PAUT and ToFD weld inspection.
- Films or images
- Handed over for your records
- Weld-by-weld report
- Density, sensitivity and interpretation for each weld
- Repair tracking
- Repairs and re-welds marked and re-shot
- Level 3 review
- Borderline indications referred to our Level 3
- NATA 12303
- ISO 9001
- AINDT
- PCN
Get in touch
Need to see inside a weld?
Swift reporting, round the clock.