Fluorescent magnetic particle inspection of drill pipe pin threads under UV-A light, magnetised with a yoke

VT · MT · PT · threads · thermal · vacuum box

Surface cracks. Made visible.

Visual, magnetic particle and dye penetrant testing, visible and fluorescent, on site or in our Darwin workshop. Plus borescope, drill pipe thread inspection, thermal imaging and vacuum box testing of tank floor welds.

  • Visual & borescope
  • MT visible & fluorescent
  • PT visible & fluorescent
  • DS-1 Vol 3 & 4
  • API RP 7G-2
  • Thermal imaging
  • Vacuum box
  • NATA MT, PT, VT

Do you need it?

Surface cracks, found and recorded.

Surface methods find cracks and defects that break the surface of a weld or component: visual inspection first, then magnetic particle (MT) on steel or dye penetrant (PT) on any metal. If you need welds, lifting gear, castings or repaired parts checked for surface cracks before they go into service or back to work, start here.

Indications are photographed, measured and marked on a sketch, with the acceptance standard cited, so every report ends in a clear accept or reject.

  1. 01

    2 methods

    Visible and fluorescent, for MT and PT.

  2. 02

    4 ways to magnetise

    Yokes, permanent magnets, coils and a bench.

  3. 03

    Site & workshop

    Offshore, on ropes or in our Darwin workshop.

  4. 04

    NATA accredited

    MT, PT and VT within scope No. 12303.

Visual inspection · VT

It starts with a good look.

Every surface inspection starts with a close visual, by inspectors who know what a weld, a casting or a worn component should look like. Weld profile, undercut, porosity, corrosion and damage are measured and recorded before any other method is chosen.

  • Welds, castings, lifting gear and pressure equipment, with weld gauges, rulers and lighting to measure what's found
  • Olympus IPLEX SA borescope: a steerable videoscope for a look inside pipes, tubes, vessels and closed sections without cutting them open, with images saved for the report

Visual inspection prior to and during service is on our NATA scope (No. 12303).

Magnetic particle · MT

Visible or fluorescent.

Visible

Black ink on white contrast

The everyday site method. Black magnetic ink over a thin white contrast coat shows a crack as a sharp black line in daylight.

Fluorescent

Under UV-A light

Fluorescent ink glows under UV-A in low light, picking up the finest cracks. Our choice for threads, shafts and critical components.

How we magnetise

The right field for the part, from site to workshop.

AC yokes

Portable electromagnets for welds and plate on site, including at height and on ropes.

Permanent magnets

No power needed, for confined spaces, hazardous areas and remote work.

Coils

Encircling coils for shafts, pins, bars and threaded connections.

MPI bench

A large bench unit in our Darwin workshop for components brought in for testing.

Steel only

MT works on ferromagnetic steel. For stainless, aluminium and copper alloys, we use penetrant.

Through thin coatings

Shallow coatings can stay on for MT. Where coatings are thick, eddy current tests through them.

Recorded

Indications photographed, measured and marked on a sketch, with the acceptance standard cited.

NATA accredited (No. 12303) for magnetic particle testing, AC magnetisation.

Dye penetrant · PT

For every metal, magnetic or not.

Penetrant draws into surface-breaking cracks and porosity, then bleeds out as a red or fluorescent line. It works on stainless steel, aluminium, copper-nickel and other non-magnetic metals that MT can't test.

Visible red dye
Red penetrant on a white developer. Quick and portable for site work.
Fluorescent
Glows under UV-A for higher sensitivity on critical parts.
Solvent removable
Aerosol kits for site, on our NATA scope.
Water washable
For batches of parts in the workshop, also on our NATA scope.
Red dye penetrant indications along a fillet weld, with a steel rule for scale
Visible red penetrant: indications along a fillet weld.

Drill pipe & drilling tools

Thread inspection to DS-1 and API RP 7G-2.

Rotary shouldered connections crack at the thread roots, often at the last engaged thread. We inspect drill pipe, drill collars, subs and drilling tools, including bits, to the standard or your specification, so worn or cracked connections come out of the string before they fail downhole.

5th editionDS-1 Vol 3Drill stem inspection: drill pipe, collars, heavyweight, subs and pup joints
5th editionDS-1 Vol 4Drilling specialty tools: inspection within the tool's maintenance process
Used drill stemAPI RP 7G-2Inspection and classification of used drill stem elements
OrYour specClient and manufacturer inspection specs, followed as written

Visual & dimensional

Threads, shoulders and seal faces checked with profile and taper gauges, to the dimensions the standard calls for.

Fluorescent MPI

Connections tested wet with fluorescent ink under UV-A, where thread-root cracks show best.

Classified & reported

Each item classified and reported to the standard, with rejects clearly identified.

Thermal imaging

See the heat before the damage.

Our FLIR E5 Pro thermal camera shows hot spots on boilers, refractory, insulation, steam lines, valves and traps while the plant is running, so failing linings and insulation are found without a shutdown.

Thermal
160 × 120 pixels, with MSX edge detail
Accuracy
±2 °C or ±2% of reading
Camera
5 MP visual image with every shot
On the image
Spot temperature and scale on every shot

Vacuum box testing

Leaks through the weld, shown as bubbles.

The weld is wet with leak detection solution, a box with a clear top is sealed over it and a vacuum of 21 to 35 kPa is drawn. Any leak through the weld shows as bubbles.

Tank floor welds

Floor lap welds leak tested with flat vacuum boxes, and the shell-to-floor corner weld with right-angle boxes. To API 650, API 653 and ASME V Article 10.

Custom sump boxes

Sumps and other awkward shapes don't suit a standard box, so we make custom vacuum boxes to fit, each with its own calibrated gauge.

Inspecting the whole tank? See piping, tank and vessel inspection.

Where we work

On site, offshore, on ropes or in the workshop.

Lifting gear, offshore and on site

Crane hooks, shackles, pad eyes and spreader bars checked by MT and visual on site, including offshore and on rope access.

Before return to service

Weld repairs, grind-outs and machined components checked before they go back to work.

What you get

A clear call, with the evidence.

Every indication is located, sized and photographed, and each item is accepted or rejected against the cited standard.

  • NATA 12303
  • ISO 9001
  • AINDT
  • PCN
Reports
NATA-endorsed for MT, PT and VT within our scope
Indication maps
Located, sized and sketched
Photos
Every indication, every rejected item
A clear call
Accept or reject against the cited standard
Cover of the DITS Surface methods brochure

Brochure

Surface methods

VT, MT and PT, borescope, threads, thermal imaging and vacuum box.

4 pages · PDF 1.0 MB

View Download PDF

Get in touch

Cracks to find or rule out?

Swift reporting, round the clock.