Technician setting up an Olympus Nortec 600 eddy current set with a pencil probe on a steel reference block

Eddy current testing · ET

Cracks found through the paint.

Eddy current testing of coated welds and tubes. Surface cracks are found through paint and coatings without blasting them off, and tubes are inspected from the inside.

  • Coated welds
  • Tube inspection
  • ISO 17643
  • WeldCheck 2
  • Nortec 600
  • Single & dual frequency

Do you need it?

Leave the coating on. Find the crack anyway.

Eddy current testing finds surface cracks in steel welds without taking the paint off. If you need coated welds checked for service cracks and don't want to blast and recoat them, this is the test to use.

Magnetic particle testing needs bare steel, so coated welds have to be blasted first and recoated after. Eddy current works through non-conductive coatings up to 2 mm thick. The set separates the coating signal from a crack signal on the screen.

  1. 01

    Through the coating

    Non-conductive coatings up to 2 mm stay in place.

  2. 02

    Small cracks

    1 × 5 mm is the smallest crack reliably found in an as-welded joint.

  3. 03

    Set up on a real slot

    Calibrated on slots of known depth, under shims as thick as the coating.

  4. 04

    Goes where you need it

    Small, battery-powered sets that go up a rope or out to a platform.

Coated welds

Tested to ISO 17643.

We test butt and fillet welds in steel 3 mm and thicker, through non-conductive coatings up to 2 mm. The weld, the heat-affected zone and 50 mm either side are scanned in two directions.

Before each job the set is calibrated on a steel reference block with spark-eroded slots 0.5, 1.0 and 2.0 mm deep, under non-conductive shims as thick as the coating. That way the coating is accounted for before a weld is tested.

The coating thickness itself is measured first, with an absolute probe, from the lift-off signal.

Standard
ISO 17643
Welds
Butt and fillet welds in steel 3 mm and thicker
Coating
Non-conductive, up to 2 mm
Coverage
Weld, HAZ and 50 mm either side, in two directions
Reference
0.5, 1.0 and 2.0 mm slots, under coating shims
Smallest crack
1 × 5 mm, reliably found in an as-welded joint

What we test

Welds, tubes and coatings.

Welds

Coated welds

Service cracks at weld toes on structures, cranes, vessels and offshore steel, with the coating left in place.

Tubes

Tube inspection

Tubes inspected from the bore. Dual frequency separates defect signals from supports and other noise.

Coatings

Coating thickness

Measured with an absolute probe from the lift-off signal, before the weld is tested.

Our sets and people

Single and dual frequency, run by certified technicians.

Single frequency

ETher WeldCheck 2

Weld inspection set built to EN 1711 and ISO 17643, 10 Hz to 20 MHz, with lift-off compensation for coatings.

Dual frequency

Nortec 600

Evident (Olympus) flaw detector for welds, tubes and surface cracks. Calibrated by Evident.

Reference blocks

Calibrated blocks

Steel reference blocks with spark-eroded 0.5, 1.0 and 2.0 mm slots, plus non-conductive shims.

PCN certified technicians

Testing is done by ISO 9712 Level 2 certified technicians as a minimum, with a Level 3 behind the procedures.

On ropes and offshore

The sets are small and battery powered, so they go up a rope or out to a platform with our technicians.

Bare steel, or need to see the indication? See surface methods for magnetic particle and penetrant testing.

NATA accredited (No. 12303) for high-frequency eddy current crack detection on metallic surfaces, including welds tested through the coating. Tube testing is outside our NATA scope.

  • NATA 12303
  • ISO 9001
  • PCN
  • AINDT
Cover of the DITS Eddy current brochure

Brochure

Eddy current

Coated welds tested through the coating, and tubes.

2 pages · PDF 0.5 MB

View Download PDF

Get in touch

Coated welds to check?

Swift reporting, round the clock.