Bruker S1 Titan handheld XRF analyser showing element results and a grade match, held over steel shafts

PMI · handheld XRF · ferrite testing

Right alloy. Right place.

Positive material identification with a Bruker S1 Titan 200 handheld XRF analyser, and ferrite testing of stainless and duplex welds. In our Darwin workshop or on site.

  • Bruker S1 Titan 200
  • Grade match
  • Ferrite testing
  • Feritscope FMP30
  • Ferrite-Check 240
  • Stainless & duplex welds
  • On site or workshop

Do you need it?

One wrong fitting can fail a whole line.

PMI tells you what alloy a part is actually made of, measured at the part in seconds. A 304 fitting in a 316 line, or a carbon steel bolt in a Cr-Mo flange, looks the same as the right one until it corrodes or cracks in service. If the wrong grade would cause you that problem, you need PMI.

We check each item against the drawing, the mill certificate or your PMI plan. On stainless and duplex welds there's a second question PMI can't answer: is the weld's ferrite content in range? Ferrite testing answers that, and we can do both in the same visit.

  1. 01

    Incoming material

    Pipe, fittings, flanges and plate checked against the mill certificate before they're built in.

  2. 02

    Welds & weld metal

    Weld metal checked against the WPS consumable, for dissimilar and alloy welds.

  3. 03

    Unknown stock

    Mixed-up or unmarked bar, plate and fittings sorted by grade before they're used.

  4. 04

    In-service plant

    Installed piping and components checked on site, for audits, repairs and replacements.

How a PMI test runs

Prepared, tested, matched and reported.

  1. 01

    Prepare

    Clean bare metal at each test point, marked and numbered.

  2. 02

    Test

    Analyser held to the surface for each shot. Repeat shots averaged where needed.

  3. 03

    Match

    Chemistry compared to the grade library and the specified grade.

  4. 04

    Report

    Item, test point, chemistry, grade match and a photo for every reading.

Our analyser

Bruker S1 Titan 200

Handheld XRF analyser. Measures elements from titanium to uranium, and matches the result to a grade library on screen.

Every day

Checked before testing

Self-check at start-up, and verified on a reference sample before each day's testing, as our PMI procedure requires.

Know the limits

No carbon reading

XRF doesn't measure carbon, so it reads 316L as 316. For L grades or carbon content, we'll tell you when you need OES or a lab instead.

Ferrite testing

Get the ferrite wrong and the weld won't last.

Austenitic stainless weld metal needs a little delta ferrite to resist hot cracking. Duplex needs the right balance of ferrite and austenite for its strength, toughness and corrosion resistance. Neither shows by eye.

A ferrite meter measures it on the weld in seconds, without cutting a sample. We test to the range in your WPS, code or client spec.

How a ferrite check runs

  • Clean bare metal at each test point, marked and numbered
  • Spot readings, or a continuous scan along the weld
  • Min, max and mean for each weld, reported against the specified range

Thin walls, tight curvature and coatings change the reading. We'll tell you when a lab section is the better check.

Procedure tests

PQR and welder test coupons checked against the range in the WPS or code.

Production welds

Duplex and stainless piping, vessels and tanks checked during fabrication.

Cladding & overlays

Austenitic cladding and weld overlays in pipes, vessels and boilers.

Cold-worked stainless

Magnetic martensite from forming or machining found and measured.

Our ferrite meters

Two meters, both magnetic induction.

Fischer

Feritscope FMP30

Range
0.1–80 %Fe, or 0.1–110 WRC-FN
Method
Magnetic induction
Recording
Readings stored on the meter, plus continuous capture for a ferrite profile along a weld
Used for
Austenitic and duplex welds, cladding and overlays

List-Magnetik

Ferrite-Check 240

Range
0.2–100 %Fe, or 0.2–140 FN
Method
Magnetic induction, to DIN EN ISO 8249
Smallest spot
ø 2 mm, for narrow welds
Recording
Scan mode along a weld. Logs 10,000 readings with min, max, mean and standard deviation

Both checks, one visit

PMI confirms the alloy. Ferrite confirms the weld.

On stainless and duplex work the two checks answer different questions, so it pays to run them together. We can do both in the same visit, on the same test points, and report them item by item.

PMI: is it the right alloy?

Element chemistry from titanium to uranium, matched to a grade library. Used on pipe, fittings, flanges, plate, bar stock and weld metal. It won't give you carbon content.

Ferrite: is the weld in range?

Ferrite content in FN or %Fe, on austenitic and duplex welds, cladding, overlays and cold-worked stainless. It won't tell you the grade: a weld can read in range and still be the wrong alloy.

What you get

Every reading, traceable to a point.

  • Numbered test points, marked on the item and on a photo
  • Chemistry and grade match for every PMI reading
  • Ferrite spot readings or a scan profile, with min, max and mean for each weld
  • Pass or fail against the drawing, mill cert, WPS or your test plan

What we need from you

The drawing or the plan.

Send us the drawing, the material list or your test plan, and we'll tell you what to test and how.

In our Darwin workshop

Bring the parts in and they're tested and reported in our workshop.

On site

The analyser and meters are portable, so installed piping and plant are tested where they stand.

Checking welds for defects too? See surface methods and radiography.

Cover of the DITS PMI and ferrite testing brochure

Brochure

PMI and ferrite testing

Handheld XRF alloy checks, and ferrite testing for stainless and duplex welds.

4 pages · PDF 0.8 MB

View Download PDF

Get in touch

Need a material or a weld checked?

Swift reporting, round the clock.